AC Series Coriolis Mass Flowmeter Wholesale
Home / Products / A Coriolis Mass Flowmeter / AC Series Coriolis Mass Flowmeter
Get in Touch

If you need any help, please feel free to contact us

Jiangsu Vner Electronic Technology Co., Ltd.
Product Brochure
Jiangsu Vner Electronic Technology Co., Ltd. Jiangsu Vner Electronic Technology Co., Ltd.
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
  • AC Series Coriolis Mass Flowmeter
Product introduction

The AC Series Coriolis Mass Flowmeters are VNERʼs flagship line for high-precision mass flow and density measurement. Based on the Coriolis effect and advanced digital signal processing, the AC Series directly measures mass flow, density and temperature, and derives volumetric flow in real time.

Driven measuring tubes generate parallel sinusoidal signals. When fluid flows through the tubes, Coriolis forces cause a controlled deformation and a measurable phase shift between inlet and outlet. The transmitter analyses this time shift to calculate mass flow, while the oscillation frequency is used for density, and integrated RTD sensors provide process temperature.

With a compact, low-pressure-loss design, extended temperature and pressure ranges, and global approvals, the AC Series is suited for custody transfer, critical process control, and high-value fluid management in demanding industrial environments.

Physical Properties

Performance and ranges are model- and configuration-dependent. Refer to the datasheet for detailed selection and sizing.

Item Description
Measuring principle Coriolis effect with controlled tube oscillation; phase shift proportional to mass flow
Measured variables Mass flow, density, process temperature; calculated volume flow
Measured media Liquids and slurries (including viscous and non-Newtonian fluids); gases; selected two-phase/multiphase mixtures (with MFDTM)
Mass flow accuracy (liquids & slurries) ±0.05 %, ±0.10 %, ±0.15 % or ±0.20 % of rate (High Accuracy / Enhanced / Standard / General)
Mass flow repeatability (liquids & slurries) ±0.02 %, ±0.05 %, ±0.075 %, ±0.10 % of rate
Volume flow accuracy (liquids & slurries) ±0.05 %, ±0.10 %, ±0.15 % or ±0.20 % of rate
Density accuracy (liquids & slurries) ±0.50, ±1.00 or ±3.00 kg/m³ (High Accuracy / Standard / General); field calibration accuracy ±0.20 kg/m³; measuring range 0–5000 kg/m³
Density repeatability ±0.25, ±0.50 or ±1.50 kg/m³
Gas mass flow accuracy ±0.25 %, ±0.50 % or ±1.00 % of rate (High Accuracy / Standard / General)
Gas mass flow repeatability ±0.15 %, ±0.25 % or ±0.50 % of rate
Temperature accuracy / repeatability ±1.0 °C accuracy; ±0.2 °C repeatability
Turndown ratio Recommended up to 20:1 for standard accuracy performance; larger turndown subject to zero stability (see sizing sheet)
Zero stability (typical) From 0.02 kg/h (AC002) to 18.0 kg/h (AC150) depending on model
Max. operating pressure Standard designs up to 10.0 MPa; higher-pressure models ≤15.0 MPa available (model- and temperature-dependent)
Secondary containment Optional containment housings with up to 2.5 MPa (AC002–AC080) and 1.5 MPa (AC100–AC150) secondary pressure rating
Process temperature range (sensor) Standard: -100...+200 °C; High-Temperature: -60...+260 °C; Ultra-High-Temperature: -60...+380 °C; Cryogenic: -196...+100 °C
Ambient temperature range (transmitter) -40...+60 °C; humidity ≤95 % RH non-condensing
Materials – wetted parts SS316 / SS316L; Hastelloy C22 and other alloys on request
Materials – housings Sensor: SS304 / SS304L or SS316 / SS316L; Transmitter: epoxy-coated aluminium or SS316 / SS316L
Approvals & safety Compliant with PED 2014/68/EU and relevant GB/ASME piping codes
Explosion protection and ingress protection Up to Ex d / Ex ib / Ex tb, IP66/67 (ATEX / IEC zones, see certificates)
Ingredient Content
Category Specification / Option Notes
Transmitter platform A-Series full-digital transmitter (DSP-based) All-digital drive and signal processing for ultra-low flow signals
Liquid & slurry performance High-accuracy classes for mass, volume and density Validated on ISO/IEC 17025-certified NIM calibration rigs
Gas measurement A-GASTM gas measurement algorithm Ultra-high frequency resolution to minimise errors from low gas density and high velocity
Two-phase / multiphase MFDTM multi-frequency drive technology Real-time multi-/variable-frequency tube excitation for improved stability under gas-liquid two-phase conditions
Diagnostics ILODTM intelligent online diagnostics NAMUR NE107-compliant diagnostic and event messages; supports predictive maintenance and lifecycle traceability
Measurement modules Concentration, composition, crude oil water-cut, online viscosity, bidirectional flow, batch functions Expandable multi-measurement platform to reduce instrument count
Analog outputs 4-20 mA (HART) Assignable to main process variables
Pulse / frequency outputs 0-10 kHz pulse / frequency For totalizing, batching and high-speed control
Digital communication HART, Modbus RS485, FOUNDATION Fieldbus, PROFINET Up to 5 configurable I/O channels with flexible combinations
PROFIBUS-PA, Ethernet-APL, discrete I/O
Installation options Integral, extended-integral, remote, wall-mounted Supports confined spaces and different ambient/temperature conditions
Low-temperature display &
operation
Clear multi-line display and
explosion-proof touch keys down to
-40°C
Operation without opening housing, suitable for
hazardous and harsh environments
Product parameters
Industry Medium / Service Typical Use
Chemical & Fine Chemicals Acids, alkalis, solvents, specialty chemicals Precision dosing, batching and recipe control; density-based quality assurance
Petrochemical & Refining LPG, diesel, gasoline, aromatics, intermediates Mass-based transfer and blending; loading/unloading and custody-related measurement (subject to local approvals)
Food & Beverage Syrups, honey, dairy fat, vegetable oils, flavourings Mass-based filling, ingredient dosing and inline density / concentration monitoring
Energy & Biofuels Biodiesel, ethanol, fuel blends Production control, transfer and distribution of biofuels
Oil & Gas (onshore/offshore) Corrosion inhibitors, methanol, scale inhibitors and other injection chemicals High-accuracy low-flow chemical injection under high pressure and tight space constraints
Water & Wastewater Treatment Coagulants, pH adjustment chemicals, antiscalants and additives Precision chemical dosing for water and wastewater treatment plants
Mining & Metallurgy Process reagents, selected slurries and pulp streams Reagent feed control and slurry mass flow monitoring within Coriolis application limits
Automotive & Industrial AdBlue (urea), lubricants, fuel additives Dosing, blending and test stand measurement in automotive and industrial applications

ABOUT US

As China AC Series Coriolis Mass Flowmeter Manufacturers and AC Series Coriolis Mass Flowmeter Factory, we are renowned for manufacturing professional and high-precision industrial instruments. Our expertise lies in providing unparalleled flow measurement resources, backed by over 12 years of experience solving complex applications.
Our precision flow metering devices are used by a diverse range of users, ranging from major oil and gas companies to photovoltaic providers, pharmaceutical manufacturers, and municipal services. We continuously contribute to the development of flow measurement in the domestic energy and chemical industries due to our expertise in measuring variable component gases and peculiar mediums.

Wenzhou Hongfeng Electrical Alloy Co., Ltd.
Certificate Of Honor
  • VNER EAC TR CU
  • VNER EAC TR CU
  • VNER AC Series CE-EMC
  • VNER LWGY Series CE-EMC
  • VNER VE Series CE-EMC
  • VNER MA80T SIL2 Approval
  • SIL
  • VNER A Series Coriolis ECM 25 ATEX-B UQ44
News